Premium IFR Boiler Suits & Coveralls Supplier in Jamnagar

Nova Industrial Supply: 22+ Years of Expertise as the Leading Stockist for Arvind, Karam & Udyogi. Ready Stock in Moti Khavdi for Fastest Delivery.

About Us

22+ Years of Excellence as a Leading IFR Workwear Supplier

Nova Industrial Supply is the most trusted stockist for Inherent Flame Resistant (IFR) solutions in Gujarat. We specialize in providing audit-ready safety gear for the Petrochemical and Power industries.

Strategically located in Moti Khavdi & Jamnagar to provide “Just-in-Time” delivery and Vendor Managed Inventory (VMI) services for large corporates.

Our Products

IFR Suit, IFR Boiler Suit & IFR Coverall Supplier in Jamnagar, Gujarat

IFR Boiler Suits

    • Heavy-duty IFR Boiler Suits with triple-needle stitching and YKK brass zippers. Designed for maximum thermal protection and long-lasting durability.

  •  

IFR Coveralls

Specialized IFR Coveralls featuring “Char Shield” technology. Fully compliant with NFPA 2112 and EN ISO 11612 for flash fire safety.

IFR Suits & Workwear

Premium IFR Suits made from a specialized Fiber Cocktail (Modacrylic + Cotton + Aramid). Oeko-Tex certified for comfort in Jamnagar’s heat.

The only place where you’ll get the perfect solution for IFR SUIT needs.

Our Contributions

Industries We Serve!

aerospace

NFPA & EN Certified

Our supplied garments meet global standards (NFPA 2112, NFPA 70E, EN ISO 11612) to ensure your workforce is always audit-ready.
oil

Inherent Protection

Unlike treated fabrics, our IFR protection is inside the fiber. It never washes out, providing life-long safety for the wearer.
automotive

Anti-Static & Arc Safe

Features an integrated Carbon Fiber Grid to prevent sparks and explosions. Proven in Manikin Tests with <50% predicted body burn.

The Comprehensive Technical Guide to Inherent Flame Resistant (IFR) Solutions

Presented by: Nova Industrial Supply | The Authorized Safety Partner

At Nova Industrial Supply, we understand that in the petrochemical and power sectors of Jamnagar, safety is not a checklist—it is a survival science. As a specialized stockist for Arvind, Karam, and Udyogi, we bridge the gap between premium manufacturing and local “Just-in-Time” availability.

This technical guide outlines the engineering, usage protocols, and commercial advantages of our IFR Workwear range.

1. The Engineering: Molecular Science vs. Chemical Coating

To the untrained eye, all orange coveralls look the same. In a flash fire, the difference is life and death.

  • Inherent (IFR) Explained: Unlike “Treated FR” cotton, where a flame-retardant chemical is applied to the fabric surface (which washes off over time), our protection is Inherent. The flame resistance is built into the molecular DNA of the fiber itself. It is permanent, unalterable, and cannot be washed out.

  • The “Char Shield” Reaction: Upon exposure to extreme heat (Flash Fire or Arc Flash), our engineered fabric instantly swells to form a rigid, carbonaceous “Char Shield.” This shield creates an oxygen-depriving barrier that blocks thermal energy transfer, preventing the skin from reaching burn thresholds.

2. The Construction: The “Tri-Blend” Matrix

We supply garments constructed from a specialized Fiber Cocktail designed specifically for high-risk industrial zones:

  • Modacrylic: The primary flame suppressor that disrupts combustion.

  • Para-Aramid: Integrates high-tensile strength (similar to ballistic body armor) to prevent the fabric from “breaking open” during a blast wave.

  • Anti-Static Carbon Grid: Visible as a subtle check pattern, this grid actively discharges static electricity to prevent spark generation in volatile environments (Zone 0/Zone 1 areas).

  • Rip-Stop Weave: Upgrading from standard Twill, our Rip-Stop technology uses a cross-hatch reinforcement grid. This ensures that a small snag from sharp machinery does not evolve into a large tear, significantly extending garment life.

3. Usage Protocols: The “Rules of Survival”

Mandatory knowledge for every Safety Officer and End-User.

  • The Layering Imperative: CRITICAL WARNING: Never wear synthetic innerwear (Polyester, Nylon, or Lycra) underneath an IFR suit. In a thermal event, synthetics will melt and fuse to the skin. Protocol: Always use 100% Cotton or FR-certified base layers.

  • The “Air Gap” Insulation: Safety wear should never be skin-tight. A slightly loose fit captures a layer of air between the fabric and body. Air is a thermal insulator that further delays heat transfer during a fire.

  • Donning Integrity: For NFPA 2112 compliance effectively, sleeves must be rolled down and buttoned, and heavy-duty YKK Brass Zippers must be fully secured to the neck.

4. Commercial Viability & ROI Analysis

For Procurement Managers, switching to Nova Industrial Supply’s IFR range offers a clear financial advantage over treated cotton.

  • Lifecycle Costing: Treated FR garments typically lose their safety rating after 30-50 washes. Our Inherent garments maintain 100% protection for the entire physical life of the fabric (3+ years). This creates a 30-40% reduction in long-term uniform costs.

  • Inventory Efficiency: With our Ready Stock in Moti Khavdi, corporate clients eliminate the need for massive warehousing. We operate as your Vendor Managed Inventory (VMI) partner, ensuring immediate availability without the carrying cost.

5. Maintenance & Audit Compliance

  • Audit-Ready Traceability: Every garment features an internal label resistant to industrial washing, allowing auditors to trace the batch and compliance history (NFPA 2112 / NFPA 70E / EN ISO 11612).

  • Wash Care for Longevity: To maintain the Low Shrinkage (<3%) and Color Fastness:

    • DO: Wash at moderate temperatures (<60°C) with mild liquid detergents.

    • DON’T: Never use Chlorine Bleach (destroys fibers) or Fabric Softeners (adds a flammable lipid layer).


Nova Industrial SupplyDelivering the Science of Safety to Jamnagar & Beyond.

Need Help with Easier IFR SUIT ? We Are Experts!

Ready Stock Hub: Moti Khavdi, Jamnagar, Gujarat Nova Industrial Supply 9712111117